Omega Vehicle Security HH507 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pomiary, testowanie i kontrola Omega Vehicle Security HH507. Omega Vehicle Security HH507 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 15
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
OMEGA
HH507
Digital Thermometer
Przeglądanie stron 0
1 2 3 4 5 6 ... 14 15

Podsumowanie treści

Strona 1 - Digital Thermometer

OMEGAHH507Digital Thermometer

Strona 2 - Servicing Europe:

Hi/Lo LIMITS mode (only Main display)Press Hi/Lo LIMITS key to enter the Hi/Lo Limits comparative mode,"LIMIT" is displayed. In the this mod

Strona 3 - SAFETY INFORMATION

3. Time set mode, (Press ENTER key can escape Time set mode) = = : = == = is displayed in third display. Time (hours, minutes, seconds) value isentere

Strona 4 - SPECIFICATIONS

10OPERATOR MAINTENANCEWARNINGTo avoid possible electrical shock, disconnect the thermocoupleconnectors from the thermometer before removing the cover.

Strona 5

1HH 506(R)/HH 507(R) CALIBRATION PROCEDURENote: The following calibration procedure should perform only by qualified technicianswho have access to the

Strona 6 - ENVIRONMENTAL

WARRANTY / DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 monthsfrom date

Strona 7 - OPERATING INSTRUCTIONS

M-2813/0799Where Do I Find Everything I Need forProcess Measurement and Control?OMEGA...Of Course!TEMPERATUREþ Thermocouple, RTD & ThermistorProbe

Strona 8

OMEGAnetSM On-Line Servicehttp://www.omega.comInternet [email protected] North America:USA: ISO 9001 Certified Canada:One Omega Drive, Box

Strona 9

1The symbol on the instrument indicates that the operator must refer to anexplanation in this manual.WARNINGTo avoid electrical shock, do not use th

Strona 10

2SPECIFICATIONSELECTRICALTemperature Scale: Celsius or Fahrenheit user-selectableMeasurement Range:Thermocouple RangeK-TYPE -200°C to 1372°C, -328°F t

Strona 11

3Accuracy: Accuracy is specified for operating temperatures over the range of18°C to 28°C (64°F to 82°F), for 1 year, not including thermocouple error

Strona 12 - OPERATOR MAINTENANCE

4ENVIRONMENTALAmbient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H.Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H.GENERAL

Strona 13

5OPERATING INSTRUCTIONS Power SwitchThe key turns the thermometer on or off. In the MIN MAX record modecan not power off, must leave MIN MAX

Strona 14 - RETURN REQUESTS / INQUIRIES

6TIMER STOP-WATCH ModePress TIMER STOP-W key to enter stop-watch mode stop-watch isdisplayed in second display. Press start/stop key to toggle stop-wa

Strona 15 - OMEGA...Of Course!

7Push MIN MAX key to cycle through the Max/Min/Avg/Present readings.If an overload is recorded, the averaging function is stopped and averagevalue dis

Komentarze do niniejszej Instrukcji

Brak uwag