Digital Thermometer & CalibratorDigital Thermometer & Calibrator
Digital Thermometer & CalibratorDigital Thermometer & Calibrator
Digital Thermometer & Calibrator
Przeglądanie stron 0
1 2 3 4 5 6 ... 18 19

Podsumowanie treści

Strona 1

CL3512ACL3512ACL3512ACL3512ACL3512ADigital Thermometer & CalibratorDigital Thermometer & CalibratorDigital Thermometer & CalibratorDigital

Strona 2 - Servicing Europe:

72.4 Source Mode Procedure (Calibration Simulation)1. Turn CL3512A on by turning selector switch to any one of the outputselector positions.2. Press T

Strona 3 - Table of contents

Source Mode Diagram8

Strona 4 - 1.0 Introduction

93.0 Operator MaintenanceWARNINGTo avoid possible electrical shock, disconnect the thermocoupleconnectors from the thermometer before removing the cov

Strona 5 - 1.2 Unpacking

104.0 SpecificationsELECTRICALTemperature Scale: Celsius or Fahrenheit user-selectableMeasurement Range:Thermocouple RangeK-TYPE(0.1°C) -200°C to 13

Strona 6 - 2.0 Operation Proceedure

GENERALDisplay: 3½ digit liquid crystal display (LCD) with a maximum reading of1999.Polarity: Automatic,positive implied,negative polarity indication.

Strona 7 - Button (HOLD Mode)

5.0 CL3152A Calibration ProcedureNote: The following calibration procedure should be performed only byqualified technicians who have access to the ite

Strona 8 - Selector Switch

13"Simulated Output" Test1. Turn the knob "COARSE" right to the end, knob of RANGE turn right tothe last two position, press "

Strona 9 - 2.3 Read Mode Proceedure

1CL3512A CALIBRATION PROCEDURESNote: The following calibration procedure should perform only by qualified technicianswho have access to the items as f

Strona 10

WARRANTY / DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 monthsfrom date

Strona 11 - Source Mode Diagram

Where Do I Find Everything I Need forProcess Measurement and Control?OMEGA...Of Course!TEMPERATURE" Thermocouple, RTD & ThermistorProbes, Con

Strona 12 - Maintenance

OMEGAnetSM On-Line Servicehttp://www.omega.comInternet [email protected] North America:USA: ISO 9001 Certified Canada:One Omega Drive, Box

Strona 13 - 4.0 Specifications

Table of contents1.0 Introduction1.1 Safety Information1.2 Unpacking2.0 Operation Procedure2.1 Unit Drawing2.2 Description of Buttons and Switches2.3

Strona 14

11.0 IntroductionThe OMEGA® CL3512A calibrator/thermometer is two meters in one. TheCL3512A simulates type J/K/T/E thermocouple signals. Each signal i

Strona 15

21.2 UnpackingRemove the packing list and verify that all equipment has been received. Ifthere are any questions about the shipment, please call the O

Strona 16

2.0 Operation Proceedure2.1 Drawing of Unit3Actual Dimensions: 195mm(H) x 92mm(W) x 53mm(D)

Strona 17

42.2 Descriptions of Buttons and Switches/ ButtonsTemperature is displayed in either degrees Celsius(°C) or degreesFahrenheit(°F). When the thermomet

Strona 18 - RETURN REQUESTS / INQUIRIES

5/ / Input SelectionsThe input selection indicates which input is selected; T1 thermocouple, T2thermocouple or the difference between the two thermoc

Strona 19 - OMEGA...Of Course!

62.3 Read Mode Proceedure1. Plug Thermocouple Sensor into input T1 and/or T2.2. Turn selector switch to Input.3. Select proper thermocouple type (J, K