Omega Vehicle Security Wireless Sensor System zSeries Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Nie Omega Vehicle Security Wireless Sensor System zSeries. Omega Vehicle Security Wireless Sensor System zSeries User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - User’s Guide

User’s Guideomega.come-mail: [email protected] Latest Product Manualsomegamanual.info®®Shop on line atzSeries Wireless Sensor System

Strona 2

41.3 Description (continued)The following example illustrates how you can hookup zSeries wireless system to yournetwork:The zSeries wireless system co

Strona 3 - TABLE OF CONTENTS

5PART 2 HARDWARE2.1 Parts of the End Device1 8 position DIP switch (under cover), sets the NID and DID of the End Device (see Section 2.7 for detail

Strona 4

2.2 Dimensions and Mounting - End DevicePosition unit where required. Mark and drill holes as required, using a #6 screw.Figure 2.2 Mounting the End

Strona 5 - LIST OF FIGURES:

72.4 Disassembly - End DeviceYou may need to open the unit for one of the following reasons:• To turn on Power Switch.• To mount unit to wall. Refer

Strona 6

82.5 Parts of the CoordinatorFigure 2.5 Parts of the Coordinator1 Wall mounting bracket clip holes (3 places)2 Label with model and serial numbers3

Strona 7

2.5 Parts of the Coordinator (continued)17 Diagnostics LED: (Yellow and Green) Diagnostics: at boot-up they light up for2 seconds, then turn off; DH

Strona 8

2.7 DIP Switches2.7.1 DIP Switch Setup: Device ID (DID)The End Device is shipped with all DIP switches in the "OFF" position.For each End

Strona 9

112.7.2 DIP Switch Setup: Network ID (NID)Each sensor network has a unique Network ID (or NID). For the End Device and the Coordinator setup the Net

Strona 10

122.7.3 DIP Switch Setup: Ethernet - CoordinatorFigure 2.9 Ethernet - 4 Position DIP Switch Setup To set the Coordinator to factory default setting

Strona 11 - SERIAL #

132.8 Network Communication Interfaces2.8.1 10Base-T RJ-45 PinoutThe 10BASE-T Ethernet network (RJ-45) system is used in the Coordinator for network

Strona 12 - External

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply.OMEGA is constantly pursuing certification of its pro

Strona 13 - • To access JTAG connector

14PART 3NETWORK CONFIGURATION3.1 Ethernet (MAC) AddressMAC (Media Access Control) address is your computer's unique hardware number.When you&apo

Strona 14

3.4 DNSDNS, Domain Name System enables individual computers and devices to be recognizedover a network based on a specific name instead of an IP addre

Strona 15

163.5.2 Changing TCP/IP Properties on Your ComputerGo to your computer’s Control Panel then Network Connections. Pick the network with the proper Et

Strona 16 - OFF ON

17PART 4OPERATIONSThis Coordinator can be used and configured in several ways, depending on user’spreference and network setup. It can be configured u

Strona 17

184.1 iConnect SoftwareThe Coordinator may also be assigned an IP Address by using the iConnect software.a) Download the iConnect software from the w

Strona 18 - Coordinator

194.1 iConnect Software (continued)d) To access the zSeries system for Configuration:Click on the “View Webpage” button, you will access the zSeries

Strona 19

204.2 Setting a New IP Address over the NetworkBesides using the iConnect software, you may use the Coordinator’s default IP addressto access it and a

Strona 20

4.3 Coordinator’s Configurations and OperationsThe Blue LED should blink for ~8 seconds and then stay on. It indicates that theCoordinator is searchi

Strona 21

4.3.1 Power Up DeviceTo verify that an End Device is working before deploying remotely, install batteries andpower it on right next to the Coordinato

Strona 22

234.3.2 Get Readings from the End DeviceOnce you see the End Device’s LED blinking periodically, it means it is sending datawhich will appear on the

Strona 23

TABLE OF CONTENTSPart 1: Introduction1.1 Safety and EMC Considerations ...21.2 Before Yo

Strona 24

4.3.2 Get Readings from the End Device (continued)While accessing the “Readings” page, If a blank screen appears without any“java application running

Strona 25 - Section 4.3 for details

4.3.3 Java Runtime Environment SetupIf your computer does not have Java installed, please download from java.sun.com. Youcan change the Java setting

Strona 26 - ACCESS CONTROL

264.3.3.2 Java Runtime Environment 1.5 (5.0) Setup instructions1. Go to your computer's Control Panel. Open the Java Plug-in 2. Click on "S

Strona 27 - ADMINISTRATOR

274.3.3.3 Browser Proxy SelectionAccessing Coordinators within your internal network• Usually when the computer and Coordinators are on an internal n

Strona 28

284.3.4 Java PolicyTo activate data logging and save graphs from the Java applets, it is necessary to createa Java Policy file and copy it onto a fol

Strona 29 - READINGS: BY GROUP

294.3.4 Java Policy (continued)5) Change Java Applet’s Runtime Parameters found on the following path:a. Control Panel --> Java --> Java Contro

Strona 30

4.3.5 ChartClick on , from the Home Page,the following page will appear. Selectthe proper Group to view the Chart. In a few seconds the following pag

Strona 31 - None High

31314.3.5 Chart (continued)Save Current Graph: Save the current graph in PNG (Portable Network Graphics)format. The filename has extension .png.Max/

Strona 32

4.3.6 DiagnosticClick on , the following page will appear.Figure 4.15 DiagnosticDate and Time: Most recent time when data is received.Save Current

Strona 33

334.3.7 ConfigurationClick on from the Home Page, the following page will appear. Figure 4.16 Configuration Name: Coordinator name [maximum of 16 a

Strona 34

TABLE OF CONTENTS(continued)4.6 ARP Protocol ...404.7 iLog

Strona 35 - Java Control Panel

344.3.7 Configuration (continued)Channel: Choose the operation channel defined in IEEE 802.15.4 for the sensor network.This allows you to select a wi

Strona 36 - Wireless Sensors ID: 24 - 31

354.3.8 Sensor Setup (continued)Figure 4.18 Sensor Setup #: Sensor ID configured by dip switches on the End Device. Click on the number to viewand m

Strona 37

4.3.8 Sensor Setup (continued)Figure 4.19 Sensor ParametersSensor Name: Name of this End Device.Update (seconds): How often this sensor is sending

Strona 38 - Diagnostic

4.3.9 Access ControlThis section describes the "Access Control" page of the Web interface. This page allowsthe users to set up the network

Strona 39 - CONFIGURATION

4.3.9 Access Control (continued)IP Address: The IP (Internet Protocol) address is a 32-bit number that identifies eachsender or receiver of informati

Strona 40 - SENSOR SETUP: BY GROUP

4.5 HTTPget Program (continued) Whenever Terminal Server service (using Port 2000 by default) is required, the # ofconnections must be set to a value

Strona 41 - SENSOR SETUP

4.5.2 HTTPget and ARP to Setup Device IP Address Use the iConnect software, which may be downloaded from our website, to dothese IP changes whenever

Strona 42 - SENSOR PARAMETERS

4.6 ARP Protocol (continued)The following window shows examples of arp commands and responses.• Your computer has an IP address of 192.168.1.118• The

Strona 43

4.7 iLog SoftwareThis is an Excel application software that can log temperature, humidity and barometricpressure from the Coordinator over the local

Strona 44

4.8 Mail Notifier SoftwareFor complete information of how to use the Mail Notifier software, click on the Help menuof the main window.The Mail Notifi

Strona 45 - C:\WINDOWS\system32\cmd.exe

LIST OF FIGURES:Figure 1.1 zSeries Wireless System on the Ethernet Network...4Figure 2.1 Parts of the End Device ...

Strona 46

4.8.2 Program Options Setup and ConfigurationComplete program setup requires: • Entering a recipient for the email• Specifying connection details to

Strona 47 - 4.6 ARP Protocol (continued)

4.8.3 Device Setting and ConfigurationMake sure that the Coordinator is configured (using web access) to the settings below. TCP Connection = any val

Strona 48

4.8.3 Device Setting and Configuration (continued)Figure 4.26 Mail Notifier Device Setting Alarm EditorOKCancelHelpAddDelBus Address/Device IDSocket

Strona 49 - Alerts List

Part 5ENVIRONMENT / OPERATING CONDITIONSEnd Device/Coordinator are designed to be fixed mounted and operated in a clean anddry environment. Care shoul

Strona 50 - Mail Server

5.1 General Deployment Guidelines (continued)7. Where possible, try to ensure an uninterrupted line-of-sight between nodes.Avoid obscuring objects (

Strona 51

5.2 With Line-of-SightWhen installing your Coordinator it is important to position your device in such a way tooptimize the antenna location within w

Strona 52 - Only Monitor Access

5.3 Without Line-of-SightWhen line-of-sight is not possible, signal penetrates and is reflected by different objectsto reach the destination. Therefo

Strona 53

5.5 Fine Adjustment in Performance1. To avoid interference from WiFi / IEEE 802.11, one could consult the figure below tochoose the best channel thro

Strona 54 - End Device

PART 6 SPECIFICATIONSSENSOR SPECIFICATIONS (zED)RELATIVE HUMIDITYAccuracy/Range: zED-BTH, zED-TH, -THP±2% for 10 to 90%; ±3% for 0 to 10% and 90 to 1

Strona 55 - COORDINATOR

EXTERNAL PROBE SPECIFICATIONS (zED)Industrial Probe: SS 316 housing, 137mm x Ø16mm (5” x Ø 0.63”) for zED-xx-BTP, zED-xx-THPStick Probe: ABS tubing, 1

Strona 57 - 2120191817161514131211

PART 7FACTORY PRESET VALUESPRESET PARAMETERS FACTORY DEFAULTSIP Address 192.168.1.200Gateway Address 0.0.0.0Subnet Mask 255.255.255.0Device Host Name

Strona 58 - PART 6 SPECIFICATIONS

APPENDIX A GLOSSARYUser of this manual should be familiar with following definitions:ARP (Address Resolution Protocol) is a protocol for mapping an In

Strona 59

Appendix B IP AddressAn IP address is a unique 32-bit address assigned to a computer and includes:• A network ID number identifying a network.• A host

Strona 60

57Appendix C IP NetmaskIP Netmask or Subnet Mask is a 32-bit pattern of ones and zeros used to determinenetwork portion of an IP address from the host

Strona 61

Appendix D ASCII ChartASCII Dec Hex Binary ASCII Dec Hex BinaryChar No Parity Char No parityNUL 00 00 00000000 @ 64 40 01000000SOH 01 01 00000001 A 65

Strona 62

Appendix D ASCII Chart Continuation/ 47 2F 00101111 o 111 6F 011011110 48 30 00110000p112 70 011100001 49 31 00110001q113 71 011100012 50 32 00110010

Strona 63

60Appendix E iLog Error MessagesError # Description Note-8003 User stopped logging readings.-10005 Failed to find the Coordinator. Ethernet cable is

Strona 64

Appendix F TELNET COMMANDS TABLECommand Device / Group ID Description (see notes below if *) ExampleERDB Device ID: 000 – 031 Get sensor readings of

Strona 65

62Appendix F TELNET COMMANDS TABLE (continued) * An example of the internal state of an End Device Command: EQNG00AResponse: 7 EngrLAB 01000010 2.07

Strona 66

Appendix G Frequently Asked Questions (FAQ)Q: Update rates are not saved after power cycling Coordinator?A: In order for the Coordinator to read bac

Strona 67

NOTES, WARNINGS and CAUTIONSInformation that is especially important to note is identified by the following labels:• NOTE • WARNING or CAUTION• IMPORT

Strona 68

Q: Nothing happens when I click on the Data Logging button, what could be wrong?A: The Java policy file is not setup properly. Make sure you get a J

Strona 69 - switch #1 must be turned ON

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1) yearfrom the

Strona 70

M4585/0408Where Do I Find Everything I Need forProcess Measurement and Control?OMEGA…Of Course!Shop on line at omega.comTEMPERATURE Thermocouple, R

Strona 71 - RETURN REQUESTS/INQUIRIES

PART 1 INTRODUCTION1.1 Safety and EMC ConsiderationsRefer to the Environment/Operating Conditions Section EMC Considerations• Whenever EMC is an is

Strona 72 - OMEGA…Of Course!

1.3 Description (continued)For example, you can select one End Device that has one internal and one externalsensor to monitor temperature and humidity

Komentarze do niniejszej Instrukcji

Brak uwag