Strona 1 - Digital Thermometer

OMEGAHH508/HH509/HH509RDigital Thermometer

Strona 2 - Servicing Europe:

8Hi/Lo LIMITS modePress Hi/Lo LIMITS key to enter the Hi/Lo Limits comparative mode,"LIMIT" is displayed. In the this mode the automatic pow

Strona 3 - SAFETY INFORMATION

9OPERATOR MAINTENANCEWARNINGTo avoid possible electrical shock, disconnect the thermocoupleconnectors from the thermometer before removing the cover.B

Strona 4 - SPECIFICATIONS

10RS-232 Operation Using Quick BASICThe following example shows how to send command instruction and receivedata responses over the RS-232 interface us

Strona 5 - ELECTRICAL

11IF C$ = "-" THEN DEC = DEC * -1END IFB$ = MID$(A$, 10, 6)DEC1 = 0N = 6FOR I = 0 TO 5 C$ = MID$(B$, N, 1) N = N - 1 D = INSTR(F$

Strona 6 - OPERATING INSTRUCTIONS

12RS-232 Transmit and Receive Comammand Summary1. Control letter should use Capital Letter.Baud rate: 1200Parity check: EVENData bits: 7Stop bits: 1&q

Strona 7 - MIN MAX record Mode

1308 — Thermocouple Type "K" ® K type"J" ® J type"T" ® T type"E" ® E type"S" ® S typeOUTPUT DATA FOR

Strona 8 - REL Relative mode

1416 — none — "-"17 — MSD18 — LSD19 — MSD20 — LSD21 — MSD22 — LSD(H)ours(M)inutes23 — Record mode "R" ® Record mode"

Strona 9

15COMMUNICATION508BRRS-232C "COM1" PORT4612-IR232RS232C CABLE1. Install the RSR232C cable between computer "COM1" and ThermometerR

Strona 10 - Hi/Lo LIMITS mode

1HH501(A,B)K / HH501(A,B)J / HH501(A,B)T / HH501(A,B)E HH508BR/HH508/HH509/HH509RCALIBRATION PROCEDURENote: The following calibration procedure should

Strona 11 - OPERATOR MAINTENANCE

WARRANTY / DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 monthsfrom date

Strona 12

OMEGAnetSM On-Line Servicehttp://www.omega.comInternet [email protected] North America:USA: ISO 9001 Certified Canada:One Omega Drive, Box

Strona 13

M-3203/0799Where Do I Find Everything I Need forProcess Measurement and Control?OMEGA...Of Course!TEMPERATUREþ Thermocouple, RTD & ThermistorProbe

Strona 14

1The symbol on the instrument indicates that the operator must refer to anexplanation in this manual.WARNINGTo avoid electrical shock, do not use th

Strona 15 - OUTPUT DATA FORMATS

2SPECIFICATIONSENVIRONMENTALAmbient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H.Storage Temperature: -20°C to 60°C (-4°F to 140°F) <7

Strona 16

3ELECTRICALTemperature Scale: Celsius or Fahrenheit user-selectable.Measurement Range:Thermocouple RangeK-TYPE(0.1°C)-200°C to 1372°C, -328°F to 1999°

Strona 17 - COMMUNICATION

4OPERATING INSTRUCTIONS Power SwitchThe key turns the thermometer on or off. In the MIN MAX record modecan not power off, must leave MIN MAX

Strona 18 - CALIBRATION PROCEDURE

5MIN MAX record ModePress MIN MAX key to enter the MIN MAX Recording mode, (displays theMaximum reading, Minimum reading, "MAX-MIN" reading

Strona 19 - RETURN REQUESTS / INQUIRIES

6 TIMER STOP-WATCH Mode (for HH501AR / HH501AS)Press TIMER STOP-W key to enter stop-watch mode stop-watch isdisplayed. Press START/STOP key to

Strona 20 - OMEGA...Of Course!

7 SET mode (Relative value set and Hi/Lo Limits value set)1. Press SET key to enter Relative valuse SET mode (Press ENTER keycan escape relative va